Home Backup Battery Sizing: Fridge, Sump Pump & 240V Well Pump Runtime Math
Practical watt-hour sizing formulas for 1kWh, 2kWh, 4–5kWh 240V modular units, and 14.3kWh wall-mount banks.
1. Account for Inverter Efficiency & Idle Draw (0.85x Rule)
AC inverters lose 10–15% to DC-to-AC conversion plus 15–45W of continuous idle overhead. Multiply nameplate capacity by 0.85 to estimate usable AC watt-hours: a 2,048Wh station delivers ~1,740Wh usable AC—enough to run a modern refrigerator (~1.2–1.5 kWh/day) plus Wi-Fi router for 24+ hours.
2. Matching Surge Watts for Sump Pumps & 240V Loads
A 1/2 HP sump pump draws ~800W running but can spike 2,000–2,400W on startup—step up to a 2kWh+ station with a 2,400W–2,600W inverter (Bluetti Elite 200 V2, EcoFlow DELTA 2 Max). For 240V well pumps or central furnace air handlers, choose a native split-phase unit like the EcoFlow DELTA Pro 3, Anker SOLIX F3800, or Jackery Explorer 5000 Plus.
3. Multi-Day Outages & Solar Recharge Pairing
Pairing a 2kWh–5kWh battery with 800W–2,400W of foldable or rigid solar panels turns a 24-hour backup box into an indefinite essentials system, often at a lower total cost than buying extra expansion batteries.